{"product_id":"north-american-rescue-jett-junctional-emergency-treatment-tool","title":"North American Rescue - JETT Junctional Emergency Treatment Tool","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNorth American Rescue’s Junctional Emergency Treatment Tool™ (JETT®) is an innovative emergency tool that delivers dual-position, belt-like compression to both legs simultaneously. JETT® from North American Rescue was designed for trauma situations and to control bleeding in the thigh or groin, areas where tourniquets are ineffective or ineffective. North American Rescue designed the JETT® to enhance the effectiveness of the JETT® in controlling bleeding in these areas. Examples of injuries that are suitable for the JETT® include stab wounds, blast injuries, and amputations. The JETT® also features a pivot lock to prevent loosening during transport, allowing the victim to be moved while simultaneously controlling bleeding.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \n\u003cspan\u003eJunctional Emergency Treatment Tool™\u003c\/span\u003e \u003cspan\u003e(JETT®)\u003c\/span\u003e Features\n\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eCompact, lightweight, and durable, ideal for field use.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eThe hemostatic device comes in a ready-to-use form, easy to use at the scene.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eThe purpose is to stop bleeding in both thighs simultaneously without affecting the patient's breathing.\u003c\/span\u003e\n\u003c\/li\u003e\n\n \u003cli role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eTwo compression devices can be independently adjusted for distance, pattern and pressure, supporting single or both leg bleeding.\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eThe buttock pad provides additional support to securely attach the device to the injured person.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eThe pivot locking system with straps and fasteners helps maintain constant pressure during the movement of the injured person.\u003c\/span\u003e\n\u003c\/li\u003e\n\n \u003cli role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003ePost-hemorrhagic time recording strip\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eThe kit comes with a simple step-by-step user guide.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eFabric sleeve that helps align the pressure pad placement and makes it easy to put on.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003eWarning\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eWhen using JETT® to stop bleeding, it should not be left in place for longer than 4 hours, as this may result in tissue death due to lack of blood supply to areas not affected by the injury.\u003c\/span\u003e\n\u003c\/li\u003e\n\n \u003cli role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eIt is used only to stop bleeding in the groin area.\u003c\/span\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003ePrecautions for use\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eShould be used only by trained personnel.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eApply additional pressure until the bleeding stops completely.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eAssess the injured person's condition every 5 minutes after transport.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli dir=\"ltr\"\u003e\n\n \u003cspan\u003ePackage size:\u003c\/span\u003e \u003cspan\u003e5.5 x 7 x 3.75 inches\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\"\u003e \n\u003cspan\u003eJETT® Overall Length:\u003c\/span\u003e \u003cspan\u003e56.75\" Fits waists up to 50\".\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\"\u003e\n\n \u003cspan\u003eWeight:\u003c\/span\u003e \u003cspan\u003e1.8 pounds\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch5 dir=\"ltr\"\u003e \u003cspan\u003eHow to use the JETT Junctional Emergency Treatment Tool\u003c\/span\u003e\n\u003c\/h5\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003eStep 1: Patient Assessment and Preparation\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eInitially assess the patient's condition to determine if the injury cannot be stopped with a standard tourniquet, such as a wound high in the thigh or groin area.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n \u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eRemove all equipment, bag contents, or debris from the patient in the area where the JETT® is to be used to prevent further injury.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eAssess the situation and consider whether the JETT® application will be used on both legs or only one leg.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003eStep 2: Usage\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eUnpack the JETT® and make it ready for use.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n \u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eInsert the belt under the injured person's body with the label that says \"This side Toward Casualty\" facing forward.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eLook for the location of the pelvic bones and pubic bones, which are connected through the inguinal ligaments.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n \u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eLift the injured person's hips and position the belt under the buttocks, centering the buttock pad and the compression pad under the groin area, confirming the groin area position.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003ePosition the compression plate so that it is parallel to the groin ligament at approximately 30 degrees, pointing inward from the midline of the body towards the toes. Then, make sure that the compression plate is in the correct position.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n \u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eDouble check that the injured person's genitals are not in a place where pressure is being applied.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eLock the buckle, then pull it tight, using your other hand to help pull, making sure there is no looseness.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eReassess the position of the pressure plate to ensure it is in the correct position.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n \u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eUse one hand to hold the base, then use your dominant hand to turn the T-shaped shaft clockwise until it is tight.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eIncrease the pressure until the bleeding stops, to the point where the bleeding is completely stopped. After that, check the distal pulse to see if it has disappeared (if the bleeding is completely stopped, the distal pulse will stop).\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n \u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eInsert the locking tab into the opening on the top of the T-spindle, then pull the base firmly to secure the device.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eRepeat as needed with the T-shaped pivot for the other leg to stabilize the bleeding in both leg injuries.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eAfter completing the hemostats, record the time after hemostats on the timer area inside the device.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eStep 3: Monitor and reassess the patient, follow up on the results.\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eThe casualty is assessed every 5 minutes (or as per the unit's medical protocol) to ensure that hemostasis remains under control.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eAssess after each transfer of the injured person to ensure that the compression plate remains in the correct position and that it continues to apply constant pressure during the transfer.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n \u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eRemoval of equipment should be done with the consent or under the supervision of a physician or field medical officer or under the medical regulations of the responsible agency.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003ePrecautions for use\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eShould be used only by trained personnel.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eApply additional pressure until the bleeding stops completely.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e \u003cspan\u003eAssess the injured person's condition every 5 minutes after transport.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp dir=\"ltr\"\u003e\u003cspan\u003eCaution:\u003c\/span\u003e \u003cspan\u003ePursuant to U.S. Federal law, this product is to be used only under the supervision\/order of a physician.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003eWarning\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eThe compression bandage should not be applied for more than 4 hours.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eIt is used only to stop bleeding in the groin area.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e","brand":"North American Rescue","offers":[{"title":"Default Title","offer_id":45439520571575,"sku":"30-0088","price":0.0,"currency_code":"THB","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8142\/2263\/files\/30-0088_a.png?v=1762940573","url":"https:\/\/valorstrategic.co.th\/en\/products\/north-american-rescue-jett-junctional-emergency-treatment-tool","provider":"VALOR STRATEGIC","version":"1.0","type":"link"}